Evaluation of semi-insulating GaAs detectors for nuclear radiation detection
- 1.0304165 - URE-Y 20030026 RIV SK eng C - Conference Paper (international conference)
Zat'ko, B. - Dubecký, F. - Gombia, E. - Žďánský, Karel - Nečas, F.
Evaluation of semi-insulating GaAs detectors for nuclear radiation detection.
Žilina: University of Žilina, 2003. ISBN 80-8070-088-5. In: Proceedings of the 9th International Workshop on Applied Physics of Condensed Matter - APCOM'2003. - (Bury, P.; Jamnický, I.; Pudiš, D.; Martinček, I.; Hockicko, P.), s. 111-114
[APCOM'2003 /9./. Malá Lučivná (SK), 11.06.2003-13.06.2003 (W)]
R&D Projects: GA AV ČR IBS2067354
Grant - others:GA SAV(SK) 2/1167/21; GA SAV(SK) 2/9015/21
Institutional research plan: CEZ:AV0Z2067918
Keywords : particle detectors
Subject RIV: JB - Sensors, Measurment, Regulation
Good performance of semi-insulating GaAs detectors with different areas of Schottky contacts and quasi-ohmic contacts is demonstrated. Current voltage and detection characteristics have been measured and high breakdown voltage has been observed. The surface potential measurements of detectors showed peculiar surface distribution. The best energy resolution of the detectors has been attained at temperature 273 K.