Number of the records: 1
The use of silicon photodiodes for x-ray diagnostics in the PALS plasma experiments
- 1.
SYSNO ASEP 0134323 Document Type J - Journal Article R&D Document Type Journal Article Subsidiary J Ostatní články Title The use of silicon photodiodes for x-ray diagnostics in the PALS plasma experiments Author(s) Ryc, L. (PL)
Badziak, J. (PL)
Juha, Libor (FZU-D) RID, ORCID, SAI
Krása, Josef (FZU-D) RID, ORCID
Králiková, Božena (FZU-D)
Láska, Leoš (FZU-D)
Parys, P. (PL)
Pfeifer, Miroslav (FZU-D) RID, ORCID, SAI
Skála, Jiří (FZU-D) RID, ORCID
Ullschmied, Jiří (UFP-V) RID
Stysz, W. (PL)
Wegrzecki, M. (PL)
Wolowski, J. (PL)Source Title Plasma Physics and Controlled Fusion. - : Institute of Physics Publishing - ISSN 0741-3335
Roč. 45, - (2003), s. 1079-1086Number of pages 8 s. Language eng - English Country GB - United Kingdom Keywords photodiodes ; x-ray ; laser-produced plasma Subject RIV BL - Plasma and Gas Discharge Physics CEZ AV0Z2043910 - UFP-V AV0Z1010921 - FZU-D Annotation Silicon photodiodes of different types were tested for the possibility of measurement of high-intensity x-ray pulses from the plasmas produced by the 1 kJ PALS laser system in Prague. The x-ray energy range of the operation of the detectors was 1-20 keV. Workplace Institute of Physics Contact Kristina Potocká, potocka@fzu.cz, Tel.: 220 318 579 Year of Publishing 2004