Number of the records: 1  

Comparison of synchronous machine cooling using heat pipe and water cooling

  1. 1.
    0103594 - UT-L 20040100 RIV PL eng J - Journal Article
    Vlach, Radek - Ondrůšek, Č.
    Comparison of synchronous machine cooling using heat pipe and water cooling.
    [Porovnání chlazení synchronního stroje užítím tepelné trubice a vodním chlazením.]
    Elektronika. Roč. 2004, 8-9 (2004), s. 195-196. ISSN 0033-2089.
    [Mechatronics 2004. Warsaw, 23.09.2004-25.09.2004]
    Institutional research plan: CEZ:AV0Z2076919
    Keywords : heat pipe * colling
    Subject RIV: BJ - Thermodynamics

    The paper is concerned with computational simulation of stator winding heating of the synchronous machine. Software ANSYS 8.0 was used for computational modeling. Computational model considers heat pipe in the middle of winding slot. The results of computer simulation show the effect of a heat pipe on winding cooling. Other simulations show the effect of direct winding cooling with water. The results of both variant of cooling were compared.

    Přispěvek se zabývá výpočtovými simulacemi oteplení statorového vinutí synchronního stroje. Pro výpočtové modelování byl využit systém ANSYS8.0. Vypočtoví model uvažuje tepelnou trubici ve středu drážky vynutí. Výsledky ukazují efekt tepelné trubice na chlazení vinutí. další simulace ukazují vliv přímého chlazení statorového vinutí vodou.
    Permanent Link: http://hdl.handle.net/11104/0010901


     
     
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.