Investigation and Control of an Induction Motor Drive under Inverter Fault Conditions
- 1.0103195 - UE-C 20043052 RIV AU eng C - Conference Paper (international conference)
Klíma, J. - Schreier, Luděk
Investigation and Control of an Induction Motor Drive under Inverter Fault Conditions.
[Výzkum a řízení pohonu s asynchronním motorem při poruše invertoru.]
Preprints of the 3rd IFAC Symposium on Mechatronic Systems. Sydney: The University of Newcastle Australia, 2004, s. 511-516.
[Symposium IFAC (International Federation of Automatic Control) on Mechatronic Systems /3./. Sydney (AU), 06.09.2004-08.09.2004]
R&D Projects: GA ČR GA102/04/0215
Keywords : electrical behaviour * frequency control * mathematical models
Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering
Improved reliability and fault tolerant operations of converter system are extremely important for industrial ac drives. In this paper an induction motor drive with fault tolerance capability is investigatedand controlled through an analytical model. After the fauled leg in the six-step voltage source inverter operation has been detected, the motor is driven by the converter reconfiguration known as the four-switch inverter, but with reduced performances
Dostatečná spolehlivost konvertorového systému a chod odolný vůči poruchám mají pro průmyslové střídavé pohony mimořádnou důležitost. V tomto příspěvku je věnována pozornost zvýšení odolnosti pohonu s asynchronním motorem vůči poruchám a jeho řízení pomocí analytického modelu. Poté, co byla při chodu napěťového invertoru se šesti řízeným spínacími prvky detekována havarovaná větev, je havarovaný konvertor i za cenu snížení výkonu rekonfigurován na investor, který je znám jako invertor se čtyřmi spínači. Existují dva možné pracovní režimy, ve kterých se různými způsoby (čtyřikrát nebo šestkrát) používají pouze čtyři možné vektory napětí