Operating Regions of Adjustable-Speed Units with Doubly Fed Machines
- 1.0100956 - UE-C 20043016 RIV CZ eng J - Journal Article
Schreier, Luděk - Chomát, Miroslav - Bendl, Jiří
Operating Regions of Adjustable-Speed Units with Doubly Fed Machines.
[Pracovní oblasti jednotek s řízenými otáčkami s dvojitě napájenými stroji.]
Acta Technica CSAV. Roč. 49, č. 2 (2004), s. 119-136. ISSN 0001-7043
R&D Projects: GA AV ČR IAA2057102
Keywords : AC machines * adjustable-speed systems * doubly fed machine
Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering
Operating regions of an adjustable-speed power unit with a doubly fed machine connected to the power grid are determined. The control range of the rotor voltage phasor is determined by means of analytical relations, considering maximal permissible values of currents and voltages of both the machine and supply cycloconverter. The results of simulation are shown to illustrate the operation of the system
Jsou určeny pracovní oblasti energetických jednotek s dvojitě napájeným strojem s řízenými otáčkami připojených k rozvodné síti. Na základě teoretického rozboru je určena oblast řízení rotorového fázoru napětí tak, aby nebyly překročeny maximální dovolené hodnoty proudů a napětí stroje i napájecího cyklokonvertoru.Uvedené výsledky simulace ilustrují chod celého systému