Number of the records: 1
Personal exposure to particles from dental nanocomposite grinding
- 1.
SYSNO ASEP 0561519 Document Type A - Abstract R&D Document Type The record was not marked in the RIV R&D Document Type Není vybrán druh dokumentu Title Personal exposure to particles from dental nanocomposite grinding Author(s) Ondráčková, Lucie (UCHP-M) RID, ORCID, SAI
Ondráček, Jakub (UCHP-M) RID, ORCID, SAI
Schwarz, Jaroslav (UCHP-M) RID, ORCID, SAI
Bradna, P. (CZ)
Roubíčková, A. (CZ)
Pelclová, D. (CZ)
Ždímal, Vladimír (UCHP-M) RID, ORCID, SAIArticle number AH-P1_005 Source Title Abstract Book. - Athens, 2022
S. 516Number of pages 1 s. Publication form Online - E Action International Aerosol Conference IAC 2022 Event date 04.09.2022 - 09.09.2022 VEvent location Athens Country GR - Greece Event type EUR Language eng - English Country GR - Greece Keywords personal exposure ; nanocomposite ; mass and number particle concentration OECD category Civil engineering Institutional support UCHP-M - RVO:67985858 Annotation The purpose of this study was to measure the personal exposure of individual participants and to compare the results with those of fixed-point monitoring. Personal nanoparticle samplers (PENS), which can simultaneously detect both nanoparticles (PM0.1) and respirable particles (PM4), were used to determine personal exposure. Area
monitoring included measurement of mass concentrations using the Berner Low Pressure Impactor (BLPI 25/0.018 /2, Hauke GmbH, Gmunden, Austria) and the Low Volume Sampler (LVS, Sven Leckel Ingenieurbüro GmbH, Berlin, Germany).Workplace Institute of Chemical Process Fundamentals Contact Eva Jirsová, jirsova@icpf.cas.cz, Tel.: 220 390 227 Year of Publishing 2023
Number of the records: 1