Number of the records: 1  

First Measurement of X-rays Generated by Runaway Electrons in Tokamaks Using a TimePix3 Device with 1 mm thick Silicon Sensor

  1. 1.
    0522781 - ÚFP 2020 RIV US eng C - Conference Paper (international conference)
    Linhart, V. - Břeň, D. - Casolari, Andrea - Čeřovský, J. - Farník, M. - Ficker, O. - Hetflejs, M. - Hron, Martin - Jakůbek, J. - Kulhánek, P. - Macúšová, E. - Marcisovsky, M. - Mlynář, J. - Svihra, P. - Svoboda, V. - Urban, Jakub - Varju, Jozef - Vrba, V.
    First Measurement of X-rays Generated by Runaway Electrons in Tokamaks Using a TimePix3 Device with 1 mm thick Silicon Sensor.
    NSS/MIC 2018 - Proceedings. New Jersey: Institute of Electrical and Electronics Engineers Inc., 2018, č. článku 8824534. ISBN 978-153868494-8.
    [IEEE Nuclear Science Symposium and Medical Imaging Conference,. Sydney (AU), 10.11.2018-17.11.2018]
    R&D Projects: GA MŠMT(CZ) LM2015045
    Institutional support: RVO:61389021
    Keywords : tokamak * silicon sensor
    OECD category: Fluids and plasma physics (including surface physics)

    An application study of modern pixel semiconductor detectors for characterization of runaway electron events in tokamaks is presented. Characterization techniques utilizing both spectroscopic measurements and monitoring of the intensity of secondary X-rays produced by the runaway electrons were used. Energy spectra of X-rays and time evolutions of their intensity on two tokamaks (Golem and Compass) were measured under different conditions and compared with results of standard runaway diagnostics. The energy spectra measured on both tokamaks have similar exponential shapes but with a significant variation in numbers of events per shot. The time evolutions of the X-ray intensity during several discharges on the tokamak Golem were measured using both the Timepix3 device and scintillation detectors (NaI:Tl and YAP:Ce). On a microsecond time scales, the signal time evolution measured by the TimePix3 device shows patterns in a form of unexpected or periodic-like increases of the intensity. We have also observed significant differences in number of events of the detected X-rays generated by the runaway electrons flying frontward and backward with respect to a limiter of the tokamak Golem. This fact declares that the runaway electrons have relativistic velocities. The experiments on the tokamak Compass provide similar results. Measurements in the immediate vicinity of tokamak Compass were impossible to perform because of a rapid change of the tokamak magnetic field. Measurements performed in the distance of at least 0.5 m from a diagnostic port of the tokamak Compass gave millions of correctly measured events per shot and an unknown number of events affected by pileups. The correctly measured events were used for construction of energy spectra and the time evolutions of the X-ray intensity.
    Permanent Link: http://hdl.handle.net/11104/0307218

     
     
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.