Number of the records: 1  

Chiral analysis and characterization of acyclic nucleoside phosphonates-based antiviral drugs by capillary electrophoresis

  1. 1.
    SYSNO ASEP0398075
    Document TypeC - Proceedings Paper (int. conf.)
    R&D Document TypeThe record was not marked in the RIV
    TitleChiral analysis and characterization of acyclic nucleoside phosphonates-based antiviral drugs by capillary electrophoresis
    Author(s) Kašička, Václav (UOCHB-X) RID, ORCID
    Šolínová, Veronika (UOCHB-X) RID, ORCID
    Sázelová, Petra (UOCHB-X) RID, ORCID
    Mikysková, Hana (UOCHB-X)
    Koval, Dušan (UOCHB-X) RID, ORCID
    Břehová, Petra (UOCHB-X) RID, ORCID
    Krečmerová, Marcela (UOCHB-X) RID, ORCID
    Janeba, Zlatko (UOCHB-X) RID, ORCID
    Holý, Antonín (UOCHB-X)
    Number of authors9
    Source TitleAnalytické metódy a zdravie človeka. 19. medzinárodná konferencia. - Bratislava : Slovenská vákuová spoločnosť, 2013 / Bodor R. ; Okenicová L. ; Staňová A. - ISBN 978-80-971179-1-7
    Pagess. 14-17
    Number of pages4 s.
    Publication formPrint - P
    ActionAnalytické metódy a zdravie človeka. Medzinárodná konferencia /19./
    Event date24.06.2013-27.06.2013
    VEvent locationRajecké Teplice
    CountrySK - Slovakia
    Event typeEUR
    Languageeng - English
    CountrySK - Slovakia
    Keywordsacyclic nucleoside phosphonates ; chiral analysis ; capillary electrophoresis
    Subject RIVCB - Analytical Chemistry, Separation
    R&D ProjectsGAP206/12/0453 GA ČR - Czech Science Foundation (CSF)
    GA13-17224S GA ČR - Czech Science Foundation (CSF)
    ME10040 GA MŠMT - Ministry of Education, Youth and Sports (MEYS)
    VG20102015046 GA MV - Ministry of Interior (MV)
    Institutional supportUOCHB-X - RVO:61388963
    AnnotationNew capillary electrophoresis (CE) methods were developed for chiral analysis and characterization of acyclic nucleoside phosphonates (ANPs)-based antivirotics and related compounds. Chiral analysis of an important anti-AIDS drug, 9-(R)-[2-(phosphonomethoxy)-propyl]adenine ((R)-PMPA, tenofovir) and related ANPs was accomplished by CE in alkaline background electrolytes (BGEs) using beta-cyclodextrin as chiral selector. Using the UV-absorption detection at 206 nm, the detection limits of the analyzed ANPs were in the submicromolar to low micromolar range.