Number of the records: 1  

Determination of key elements in plant samples by inductively coupled plasma optical emission spectrometry with electrothermal vaporization

  1. 1.
    0510225 - ÚOCHB 2020 RIV SK eng J - Journal Article
    Šerá, Luisa - Loula, Martin - Matějková, Stanislava - Mestek, O.
    Determination of key elements in plant samples by inductively coupled plasma optical emission spectrometry with electrothermal vaporization.
    Chemical Papers. Roč. 73, č. 12 (2019), s. 3005-3017. ISSN 2585-7290. E-ISSN 1336-9075
    Institutional support: RVO:61388963
    Keywords : optical emission spectrometry * inductively coupled plasma * plants * electrothermal vaporization * trace elements
    OECD category: Analytical chemistry
    Impact factor: 1.680, year: 2019
    Method of publishing: Limited access
    https://link.springer.com/article/10.1007/s11696-019-00858-y

    Inductively coupled plasma optical emission spectrometry combined with electrothermal vaporization (ETV) was used for determination of Ba, Ca, Co, Cu, Fe, K, Mg, Mn, P, Sr, Zn, S, and Se in plant materials. Optimized temperature program comprised a pyrolysis phase (duration 60 s and max. temperature 600 degrees C) and analytical phase (duration 70 s and temperature gradually increasing to 2500 degrees C), dichlorodifluoromethane (known as Freon R12) was used as a chemical modifier. High plasma power for robust plasma conditions was used. Calibrations based on certified reference materials of plant and animal origin and aqueous calibration solutions were linear for most of the used spectral lines and were stable for several months. Limits of detection were in the range from 7 to 1100 mg/kg for plant main elements and from 0.074 to 4.3 mg/kg for plant minor and trace elements. The precision of results was below 6%, and recovery was 83-116%. Results of inductively coupled plasma optical emission spectrometry with ETV were in good agreement with results of inductively coupled plasma optical emission spectrometry with pneumatic nebulization sample introducing system and inductively coupled plasma mass spectrometry obtained in the same laboratory, and differences between results were generally lower than 10%. Then, the amounts of selected elements, which are important indicators of plant health and nutritional value, were determined. The agreement of our results with results obtained in another laboratory was acceptable in case of S, K, Ca, and Se (differences lower than 10%). In case of determination of Mg, P, Cu, Mn, and Zn, the differences ranged from 20 to 25%.
    Permanent Link: http://hdl.handle.net/11104/0300754

     
     
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.