Number of the records: 1  

Histology and micro-CT study of diamond-coated metal bone implants in rabbit femurs

  1. 1.
    SYSNO ASEP0496851
    Document TypeC - Proceedings Paper (int. conf.)
    R&D Document TypeConference Paper
    TitleHistology and micro-CT study of diamond-coated metal bone implants in rabbit femurs
    Author(s) Potocký, Štěpán (FZU-D) RID, ORCID
    Ižák, Tibor (FZU-D) RID
    Dragounová, Kateřina (FZU-D) ORCID
    Kromka, Alexander (FZU-D) RID, ORCID, SAI
    Rezek, Bohuslav (FZU-D) RID, ORCID
    Mandys, V. (CZ)
    Bartoš, M. (CZ)
    Bačáková, Lucie (FGU-C) RID, ORCID
    Sedmera, David (FGU-C) RID, ORCID, SAI
    Number of authors9
    Source TitleNanocon 2017 : conference proceedings : 9th International Conference on Nanomaterials - Research & Application. - Ostrava : Tanger Ltd., 2018 - ISBN 9788087294819
    Pagess. 573-577
    Number of pages5 s.
    Publication formOnline - E
    ActionNANOCON 2017. International Conference on Nanomaterials - Research & Application /9./
    Event date18.10.2017 - 20.10.2017
    VEvent locationBrno
    CountryCZ - Czech Republic
    Event typeWRD
    Languageeng - English
    CountryCZ - Czech Republic
    Keywordsscrew implant ; diamond coating ; osteointegration ; histology
    Subject RIVBO - Biophysics
    OECD categoryBiophysics
    Subject RIV - cooperationInstitute of Physiology - Biotechnology ; Bionics
    R&D ProjectsNV15-32497A GA MZd - Ministry of Health (MZ)
    Institutional supportFZU-D - RVO:68378271 ; FGU-C - RVO:67985823
    UT WOS000452823300094
    EID SCOPUS85051922747
    AnnotationA conformal coating of a thin diamond layer on three-dimensional metal bone implants was shown directly on stainless steel and TiAl6V4 cortical screw implant using ultrasonic and composite polymer pretreatment method. The best conformation coverage was achieved in the case of the WO3 interlayer for both stainless steel and TiAl6V4 screws. The process of osteointegration of the screw implants into rabbit femurs is evidenced by the formation of a bone edge via desmogenous ossification around the screws in less than six months after implantation. A detailed evaluation of the tissue reaction around the implanted screws shows good biocompatibility of diamond-coated metal bone implants.
    WorkplaceInstitute of Physics
    ContactKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Year of Publishing2019
Number of the records: 1  