Number of the records: 1  

DHCAL with minimal absorber: measurements with positrons

  1. 1.
    SYSNO ASEP0465285
    Document TypeJ - Journal Article
    R&D Document TypeJournal Article
    Subsidiary JČlánek ve WOS
    TitleDHCAL with minimal absorber: measurements with positrons
    Author(s) Freund, B. (US)
    Neubueser, C. (US)
    Schlereth, J. (US)
    Cvach, Jaroslav (FZU-D) RID, ORCID
    Gallus, Petr (FZU-D) RID
    Havránek, Miroslav (FZU-D) RID
    Janata, Milan (FZU-D) RID
    Kovalčuk, Michal (FZU-D)
    Kvasnička, Jiří (FZU-D) RID, ORCID
    Lednický, Denis (FZU-D)
    Marčišovský, Michal (FZU-D) RID, ORCID
    Polák, Ivo (FZU-D) RID, ORCID
    Popule, Jiří (FZU-D) RID, ORCID
    Tomášek, Lukáš (FZU-D) RID, ORCID
    Tomášek, Michal (FZU-D) RID
    Růžička, P. (CZ)
    Šícho, Petr (FZU-D) RID, ORCID
    Smolík, Jan (FZU-D) RID, ORCID
    Vrba, Václav (FZU-D) RID, ORCID
    Zálešák, Jaroslav (FZU-D) RID, ORCID
    Number of authors103
    Article numberP05008
    Source TitleJournal of Instrumentation. - : Institute of Physics Publishing - ISSN 1748-0221
    Roč. 11, May (2016), 1-24
    Number of pages24 s.
    Languageeng - English
    CountryGB - United Kingdom
    Keywordscalorimeter methods
    Subject RIVBF - Elementary Particles and High Energy Physics
    R&D ProjectsLG14033 GA MŠMT - Ministry of Education, Youth and Sports (MEYS)
    7E12050 GA MŠMT - Ministry of Education, Youth and Sports (MEYS)
    Institutional supportFZU-D - RVO:68378271
    UT WOS000377851700031
    EID SCOPUS84969194711
    DOI10.1088/1748-0221/11/05/P05008
    AnnotationIn special tests, the active layers of the CALICE Digital Hadron Calorimeter prototype, the DHCAL, were exposed to low energy particle beams, without being interleaved by absorber plates. The thickness of each layer corresponded approximately to 0.29 radiation lengths or 0.034 nuclear interaction lengths, defined mostly by the copper and steel skins of the detector cassettes. This paper reports on measurements performed with this device in the Fermilab test beam with positrons in the energy range of 1 to 10 GeV. The measurements are compared to simulations based on GEANT4 and a standalone program to emulate the detailed response of the active elements.
    WorkplaceInstitute of Physics
    ContactKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Year of Publishing2017
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.