Number of the records: 1
Performance of a coal pillar at deeper cover: Field and simulation studies
- 1.
SYSNO ASEP 0504426 Document Type J - Journal Article R&D Document Type Journal Article Subsidiary J Článek ve WOS Title Performance of a coal pillar at deeper cover: Field and simulation studies Author(s) Kumar, A. (IN)
Waclawik, Petr (UGN-S) RID
Singh, R. (IN)
Ram, S. (IN)
Korbel, J. (CZ)Number of authors 5 Source Title International Journal of Rock Mechanics and Mining Sciences. - : Elsevier - ISSN 1365-1609
Roč. 113, č. 1 (2019), s. 322-332Number of pages 11 s. Publication form Online - E Language eng - English Country GB - United Kingdom Keywords strength ; failure ; room and pillar Subject RIV DH - Mining, incl. Coal Mining OECD category Mining and mineral processing R&D Projects LO1406 GA MŠMT - Ministry of Education, Youth and Sports (MEYS) Method of publishing Limited access Institutional support UGN-S - RVO:68145535 UT WOS 000454150800029 EID SCOPUS 85058637629 DOI 10.1016/j.ijrmms.2018.10.006 Annotation Exhaustion of coal reserve, extractable by conventional longwall method of working at Czech mines, provided an opportunity to try modified Room and Pillar method to extract high grade coal locked-up in larger shaft protection pillar at around 900m depth. The shaft pillar is divided into various Room and Pillar panels and the development process in a panel followed a constant gallery width of 5.2m and 3.5m height. This development in the shaft pillar by bolter miner resulted oblique and inclined pillars of 860–1225m2 area. Stability of these pillars is realised to be vital for optimum recovery of high-grade coal from these panels. No empirical formulation is found suitable for the design of pillars at such a depth. Therefore, an attempt is made to select a better representing one through comparative study of the available formulation. CMRI formula is found to be an alternative solution for designing pillars at this depth as it contains depth of cover as a design parameter.
This parameter in the formulation is included to take care of the in situ stress conditions and compactness of the material at higher depth of cover. Further, a number of geo-technical instruments are installed in two pillars of Panel V for an analysis of their stability during the development. An attempt is made to develop a strainsoftening based numerical modelling approach, calibrated by field studies and CMRI empirical formulation, to assess pillar performance at deeper cover. This development is found to be helpful in pillar stability analysis, when the installed instruments ceased to work. Further, an apprehension of pillar failure by extrapolation of field results is not confirmed on simulated models. This paper briefly presents a discussion of difficulties involved in pillar design at higher depth followed by results of field and simulation conducted for the deep Czech mine.Workplace Institute of Geonics Contact Lucie Gurková, lucie.gurkova@ugn.cas.cz, Tel.: 596 979 354 Year of Publishing 2020 Electronic address https://www.sciencedirect.com/science/article/pii/S1365160918303630?via%3Dihub
Number of the records: 1