Number of the records: 1  

Evaluation of antimony migration from pewter cups using a trap-and-atomizer device for HG-AAS

  1. 1.
    0350127 - ÚIACH 2011 RIV AR eng A - Abstract
    Dessuy, M. B. - Kratzer, Jan - Dědina, Jiří - Vale, M. G. R. - Welz, B.
    Evaluation of antimony migration from pewter cups using a trap-and-atomizer device for HG-AAS.
    Eleventh Rio Symposium on Atomic Spectrometry. Book of Abstracts. 2010. s. 232.
    [Rio Symposium on Atomic Spectrometry /11./. 24.10.2010-29.10.2010, Mar del Plata]
    R&D Projects: GA ČR GA203/09/1783
    Institutional research plan: CEZ:AV0Z40310501
    Keywords : antimony * HG-AAS * AAS
    Subject RIV: CB - Analytical Chemistry, Separation
    http://www.11thriosymposium.com.ar/index.htm

    The goal of this work was to determine the amount of Sb leached from pewter cups to an acetic acid solution, kept in contact with cups during different time. Sb was determined by hydride generation - atomic absorption spectrometry using in-atomizer preconcentration. A trap-and-atomizer device was employed. This device is the (multiatomizer with the inlet arm modified to serve as the trap.
    Permanent Link: http://hdl.handle.net/11104/0190210

     
     
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.