Number of the records: 1
Diagnostics of magnetized low temperature plasma by ball-pen probe
- 1.0382735 - ÚFP 2013 RIV PL eng J - Journal Article
Adámek, Jiří - Peterka, M. - Gyergyek, T. - Kudrna, P. - Tichý, M.
Diagnostics of magnetized low temperature plasma by ball-pen probe.
Nukleonika. Roč. 57, č. 2 (2012), s. 297-300. ISSN 0029-5922. E-ISSN 1508-5791.
[International Conference on Research and Applications of Plasmas (PLASMA). Warsaw, 12.09.2011-16.09.2011]
R&D Projects: GA ČR GA202/07/0044; GA AV ČR KJB100430901
Institutional research plan: CEZ:AV0Z20430508
Keywords : ball-pen probe * magnetron
Subject RIV: BL - Plasma and Gas Discharge Physics
Impact factor: 0.507, year: 2012
http://www.nukleonika.pl/www/back/full/vol57_2012/v57n2p297f.pdf
The ball-pen probe is an innovative electric probe for direct measurements of the plasma potential in magnetized hot plasma. This probe is based on the Katsumata probe concept. The ball-pen probe can adjust the ratio I-saturat(-)/I-saturat(+) of the electron and ion saturation currents to be equal to one and therefore the ball-pen probe characterization becomes symmetric. If this is achieved, the floating potential of the ball-pen probe is equal to the plasma potential in Maxwellian plasma. We show the application of a ball-pen probe in slightly magnetized low temperature plasma
Permanent Link: http://hdl.handle.net/11104/0212869
Number of the records: 1