Number of the records: 1  

Detection of metallothionein as a melanoma marker by LA-ICP-MS combined with sample pretreatment by using magnetic particles coated with an imprinted polymeric layer

  1. 1.
    0574401 - ÚŽFG 2024 RIV GB eng J - Journal Article
    Veverková, K. - Pavelicová, K. - Vlčnovská, M. - Vejvodová, M. - Horák, Vratislav - Kanický, V. - Adam, V. - Vaculovič, T. - Vaculovičová, M.
    Detection of metallothionein as a melanoma marker by LA-ICP-MS combined with sample pretreatment by using magnetic particles coated with an imprinted polymeric layer.
    Journal of Analytical Atomic Spectrometry. Roč. 38, č. 8 (2023), s. 1618-1625. ISSN 0267-9477. E-ISSN 1364-5544
    R&D Projects: GA MŠMT(CZ) LQ1601; GA ČR(CZ) GA20-02203S; GA MŠMT(CZ) EF16_019/0000785
    Institutional support: RVO:67985904
    Keywords : melanoma * metallothionein
    OECD category: Oncology
    Impact factor: 3.4, year: 2022
    Method of publishing: Limited access
    https://asep.lib.cas.cz/arl-cav/cs/csg/?repo=crepo1&key=5452124316

    Effective detection and sensitive quantification of disease markers enable a better understanding of processes leading to disease development. Therefore, we present an approach that combines the excellent selective recognition capabilities of molecularly imprinted polymers (MIPs) and sensitive elemental detection using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Dopamine was used as a functional monomer, and metallothionein (MT), a metal-containing protein (Zn and Cd), was the targeted tumor marker. Iron oxide magnetic particles were exploited as a carrier of the polymeric layer. Due to the agglomeration of the particles in the presence of an external magnet, the prepared molecularly imprinted polymers (Mag-MIPs(MT)) were capable of isolating MT molecules from a tissue sample. A sandwich immunoassay with antibodies labeled by using silver nanoparticles was used to confirm the binding of MT to Mag-MIPs(MT). The calculated efficiency of isolation from a standard MT solution (73.5 & mu,M) was 63.3% (46.5 & mu,M). Casein was used to verify the selectivity of the prepared Mag-MIPs. The prepared particles were used for sensitive quantification of MT in melanoma and healthy skin of the melanoma-bearing Libechov minipig (MeLiM), which confirms that this method is applicable for the investigation of the tumor microenvironment. We found a significantly higher content of Zn in tumor tissue than in healthy skin.
    Permanent Link: https://hdl.handle.net/11104/0344726

     
     
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.