Antimony Hall sensor testing at ITER and DEMO relevant temperatures

  1. 1.
    0571916 - ÚFP 2024 RIV NL eng J - Journal Article
    Entler, Slavomír - Ďuran, Ivan - Šimonovský, M. - Řeboun, J. - Turjanica, P. - Šobáň, Zbyněk - Sládek, Petr - Viererbl, L.
    Antimony Hall sensor testing at ITER and DEMO relevant temperatures.
    Fusion Engineering and Design. Roč. 189, April (2023), č. článku 113476. ISSN 0920-3796. E-ISSN 1873-7196
    R&D Projects: GA MŠMT(CZ) EF16_019/0000768; GA TA ČR(CZ) TK03030070; GA MŠMT EF16_013/0001405
    EU Projects: European Commission(BE) 101052200
    Grant - others:AV ČR(CZ) StrategieAV21/27
    Program: StrategieAV
    Research Infrastructure: CzechNanoLab - 90110; CzechNanoLab II - 90251
    Institutional support: RVO:61389021 ; RVO:68378271
    Keywords : Antimony * demo * Hall sensor * iter * Magnetic diagnostics * Steady-state
    OECD category: Fluids and plasma physics (including surface physics); Condensed matter physics (including formerly solid state physics, supercond.) (FZU-D)
    Impact factor: 1.7, year: 2022
    Method of publishing: Limited access
    https://www.sciencedirect.com/science/article/pii/S0920379623000601?via%3Dihub

    Measurements of the steady-state magnetic field of ITER and DEMO reactors will be performed by Hall sensors that will be part of the magnetic diagnostics. The sensors will contribute to the measurement of the plasma current, plasma-wall clearance, and local perturbations of the magnetic flux surfaces near the wall. The paper describes new ceramic-metal Hall sensors with an antimony sensing layer. The results of temperature tests of second-generation antimony sensors based on thick printed copper technology are presented, including testing of the long-term stability of the sensors.