Hydride trapping in quartz atomizers: possibilities and limitations

  1. 1.
    0381143 - ÚIACH 2013 BR eng A - Abstract
    Kratzer, Jan - Musil, Stanislav - Vobecký, Miloslav - Dědina, Jiří
    Hydride trapping in quartz atomizers: possibilities and limitations.
    Book of abstracts & Scientific Program. 12th Rio Symposium on Atomic Spectrometry. 2012. s. 64.
    [Rio Symposium on Atomic Spectrometry /12./. 17.09.2012-21.09.2012, Foz do Iguacu]
    R&D Projects: GA ČR(CZ) GPP206/11/P002
    Institutional support: RVO:68081715
    Keywords : trap-and-atomizer device * plumbane * 212Pb radiotracer study

    A 212Pb radioactive indicator was used to verify the plumbane generation and preconcentration conditions in a quartz trap-and-atomizer device. Bismuth was found as the strongest interferent and it was shown that the interference takes place during the trapping step of the preconcentration mode.
    Permanent Link: http://hdl.handle.net/11104/0211675

     
    FileDownloadSizeCommentaryVersionAccess
    20120070.pdf2313.9 KBPublisher’s postprintopen-access
     