Number of the records: 1
Design of Experimental Setup for Investigation of Cavitation Bubble Collapse Close to a Solid Wall
- 1.0353201 - ÚT 2011 RIV CZ eng C - Conference Paper (international conference)
Müller, M. - Zima, Patrik - Unger, J. - Živný, M.
Design of Experimental Setup for Investigation of Cavitation Bubble Collapse Close to a Solid Wall.
International Conference Experimental Fluid Mechanics 2010. Vol. 1. Liberec: Technical University of Liberec, 2010 - (Vít, T.; Dančová, P.), s. 427-430. ISBN 978-80-7372-670-6.
[International Conference Experimental Fluid Mechanics 2010. Liberec (CZ), 24.11.2010-26.11.2010]
R&D Projects: GA ČR GAP101/10/1428
Institutional research plan: CEZ:AV0Z20760514
Keywords : cavitation bubble * collapse * experimental setup
Subject RIV: BK - Fluid Dynamics
This paper describes the experimental setup for the investigation of the impact load from cavitation bubble collapse on a solid wall. The vapour bubble is generated inside a chamber by localized heating. The bubble collapse is initiated by a piezoelectric actuator. The collapse impact load is measured by PVDF piezoelectric transducer. The collapse is recorded by high speed CCD camera and the pressure inside the chamber is measured by dynamics pressure transducer. The system is controlled by LabView software.
Permanent Link: http://hdl.handle.net/11104/0192513
Number of the records: 1