Number of the records: 1  

Shaped asymmetric RF pulse for frequency selective excitation in magnetic resonance (p10s3o3)

  1. 1.
    SYSNO ASEP0047358
    Document TypeL - Prototype, Functional Specimen
    R&D Document TypePrototype, Functional Specimen
    TitleShaped asymmetric RF pulse for frequency selective excitation in magnetic resonance (p10s3o3)
    TitleTvarovaný asymetrický RF puls pro frekvenčně selektivní excitaci v magnetické rezonanci (p10s3o3)
    Author(s) Starčuk, Zenon (UPT-D) RID
    Starčuk jr., Zenon (UPT-D) RID, ORCID, SAI
    Year of issue2001
    Int.Codep10s3o3
    SResult web page, Location of the resultMed Univ Vienna, Wien, AT; Bruker Biospin GmbH, Rheinstetten, DE; Center for Magn. Reson. Research, Dept. of Radiology, Univ. of Minnesota, Minneapolis, MN
    Technical parametersAmplitudově modulovaný RF puls pro frekvenčně selektivní MR excitaci s velmi asymetricky umístěným časovým ohniskem. V páru se svým zrcadlovým obrazem je vhodný pro in vivo MR spektroskopii s lokalizací STEAM a extrémně krátkým echo-časem.
    Economic parametersPuls umožňuje extrémní zkrácení echo-času při in vivo MR spektroskopii s lokalizací metodou STEAM (až TE<1ms). Tím zvýšuje kvalitu MR spekter a v silných polích umožňuje detekci většího počtu metabolitů.
    Owner NameÚstav přístrojové techniky AV ČR
    Registration Number of the result owner68081731
    Use by another entityA - Pro využití výsledku jiným subjektem je vždy nutné nabytí licence
    License fee feeZ - Poskytovatel licence nepožaduje v některých případech licenční poplatek
    Languageeng - English
    CountryCZ - Czech Republic
    Keywordsmagnetic resonance spectroscopy ; excitation pulse
    Subject RIVFS - Medical Facilities ; Equipment
    CEZAV0Z2065902 - UPT-D
    AnnotationAmplitude-modulated asymmetric RF pulse for frequency-selective excitation, most notably for slice selection in localized in-vivo MR spectroscopy. This pulse is a further optimized version of the pulse given in 1999 to CMRR (Univ. of Minnesota) for testing and incorporation in a VAPOR-STEAM pulse sequence with extremely short echo time. The unique results achieved are the basis for the popularity of the then published pulse sequence. The digital template of this pulse is provided on contractual basis.
    WorkplaceInstitute of Scientific Instruments
    ContactMartina Šillerová, sillerova@ISIBrno.Cz, Tel.: 541 514 178
    Year of Publishing2006