Number of the records: 1  

Inspection of local wall thinning by different magnetic methods

  1. 1.
    0510462 - FZÚ 2020 RIV US eng J - Journal Article
    Vértesy, G. - Gasparics, A. - Tomáš, Ivan
    Inspection of local wall thinning by different magnetic methods.
    Journal of Nondestructive Evaluation. Roč. 37, č. 3 (2018), s. 1-8, č. článku 65. ISSN 0195-9298. E-ISSN 1573-4862
    R&D Projects: GA ČR GB14-36566G
    Institutional support: RVO:68378271
    Keywords : pipe * magnetic NDT * local wall thinning * magnetic adaptive testing * magnetic flux leakage measurement
    OECD category: Condensed matter physics (including formerly solid state physics, supercond.)
    Impact factor: 2.139, year: 2018
    Method of publishing: Limited access
    https://doi.org/10.1007/s10921-018-0515-z

    The applicability of three different magnetic methods, Magnetic flux leakage technique (MFL), Magnetic adaptive testing and Metal memory method (MMM) was tested for detection of an artificial slot in a system of three steel plates. It was found that MAT resulted in the best signal/noise ratio, and it is capable to detect the bottom side slot even in the three layer configuration. MFL also resulted in acceptable signal/noise ratio in the two layer configuration, but it was not able to detect the slot through two other plates. MMM was not found to be suitable for unstressed and un-magnetized slot detection in the given experimental arrangement.
    Permanent Link: http://hdl.handle.net/11104/0300935

     
     
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.