Infuence of Isomeric Composition and Sample Handling on the Liquid Density of Hydrofuorethers Measured by Vibrating Tube Densimeter at 0.1 MPa

  1. 1.
    0574344 - ÚT 2024 RIV US eng J - Journal Article
    Prokopová, Olga - Blahut, Aleš - Hajduch, J. - Kučnirová, K. - Čenský, Miroslav - Aminian, Ali - Richter, M. - Vinš, Václav
    Infuence of Isomeric Composition and Sample Handling on the Liquid Density of Hydrofuorethers Measured by Vibrating Tube Densimeter at 0.1 MPa.
    International Journal of Thermophysics. Roč. 44, č. 9 (2023), č. článku 139. ISSN 0195-928X. E-ISSN 1572-9567
    R&D Projects: GA ČR(CZ) GA22-03380S
    Institutional support: RVO:61388998
    Keywords : hydrofluoroether * isomer * liquid density * vibrating tube densimeter
    OECD category: Thermodynamics
    Impact factor: 2.2, year: 2022
    Method of publishing: Open access
    https://link.springer.com/article/10.1007/s10765-023-03247-6#Fun

    Hydrofluoroethers (HFEs) represent a new family of promising engineering fluids suitable for technical cleaning and cooling of electronic and magnetic devices or as admixtures in refrigerant blends. Here, we report accurate data for the liquid density at 0.1 MPa and temperatures from 273.15K to 343.15K for a series of five HFEs, namely, HFE-7000, HFE-7100, HFE-7200, HFE-7300, and HFE-7500. A highly sensitive vibrating tube densimeter with a borosilicate glass U-tube calibrated according to the procedure by Prokopova et al. (J Chem Thermodyn 173:106855, 2022) provided density data with an expanded uncertainty ( k = 2) of 0.13 kg center dot m(-3). Influences such as sample degassing, water content, or sample temperature before its dosing into the densimeter are discussed. Thanks to the high sensitivity of the used densimeter, an unexpected shift in the density of different HFE-7100 and HFE-7200 liquid samples was detected. Unlike other HFEs, HFE-7100 and HFE-7200 are mixtures of two hardly separable isomers, which were so far considered having identical thermophysical properties. Utilizing nuclear magnetic resonance spectroscopy, the ratio of n-isomer and iso-isomer was inspected for various liquid samples. In the range of iso-isomer mole fraction from 0.61 to 0.77, the new measurements revealed density differences of more than 5 kg center dot m(-3) in case of HFE-7100 and of about 3 kg center dot m(-3) in case of HFE-7200. Consequently, for some applications, the properties of different HFE isomers cannot be considered identical. The Rackett-type correlation for the saturated liquid density was fitted using the new and the literature data.
    Permanent Link: https://hdl.handle.net/11104/0348156

     
     