Number of the records: 1  

Design and first tests of the S-3 detector of reactor antineutrinos

  1. 1.
    SYSNO ASEP0557506
    Document TypeC - Proceedings Paper (int. conf.)
    R&D Document TypeConference Paper
    TitleDesign and first tests of the S-3 detector of reactor antineutrinos
    Author(s) Slavíčková, M. (CZ)
    Belov, V. (RU)
    Broulím, J. (CZ)
    Brudanin, V. (RU)
    Egorov, V. (RU)
    Fajt, L. (CZ)
    Fomina, M. (RU)
    Hodák, R. (CZ)
    Kazartsev, S. (RU)
    Kruliš, Zdeněk (UMCH-V) RID, ORCID
    Macko, M. (CZ)
    Mašek, P. (CZ)
    Michálková, Danuše (UMCH-V)
    Petro, M. (CZ)
    Přidal, P. (CZ)
    Rukhadze, E. (CZ)
    Shevchik, E. (RU)
    Smolek, K. (CZ)
    Slavíček, T. (CZ)
    Štekl, I. (CZ)
    Zhitnikov, I. (RU)
    Article number11011
    Source TitleEPJ Web of Conferences, ANIMMA 2021 – Advancements in Nuclear Instrumentation Measurement Methods and their Applications, 253. - Les Ulis : E D P Sciences, 2021 - ISSN 2100-014X
    Number of pages5 s.
    Publication formPrint - P
    ActionConference on Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA)
    Event date21.06.2021 - 25.06.2021
    VEvent locationPrague
    CountryCZ - Czech Republic
    Event typeWRD
    Languageeng - English
    CountryFR - France
    KeywordsS3 experiment ; reactor neutrinos ; neutrino oscillations
    Subject RIVCD - Macromolecular Chemistry
    OECD categoryPolymer science
    Institutional supportUMCH-V - RVO:61389013
    UT WOS000788459400095
    DOI10.1051/epjconf/202125311011
    AnnotationThe new experiment S3 devoted to the study of reactor antineutrinos was designed and constructed as a common activity of IEAP CTU in Prague and JINR (Dubna). The S3 detector is a compact, highly segmented polystyrene-based scintillating detector composed of 80 detector elements with a gadolinium neutron converter between elements layers. A positron and a neutron are produced in an inverse beta decay initiated with an electron antineutrino in the detector. A modular multi-channel fast ADC was developed for the data acquisition for the whole 80-channel S3 detector and the 4-channel cosmic veto system. The detector meets very strict safety rules of nuclear power plants and can be installed in a chamber located immediately under the reactor. The close vicinity from the reactor enables to study neutrino properties with a higher efficiency, to investigate neutrino oscillations at short baselines and try to verify the hypothesis of a sterile neutrino. The details of the design and construction of the S3 detector, as well as properties of the modular multi-channel fast ADC system, and first tests of the device are presented.
    WorkplaceInstitute of Macromolecular Chemistry
    ContactEva Čechová, cechova@imc.cas.cz ; Tel.: 296 809 358
    Year of Publishing2023
    Electronic addresshttps://www.epj-conferences.org/articles/epjconf/abs/2021/07/epjconf_animma2021_11011/epjconf_animma2021_11011.html
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.