Number of the records: 1  

Distribution of the external wind pressure coefficients on the surface of the façade of the high‐rise building 'KINEUM' determined from the wind tunnel measurements

  1. 1.
    0518876 - ÚTAM 2020 RIV CZ eng V - Research Report
    Hračov, Stanislav - Macháček, Michael
    Distribution of the external wind pressure coefficients on the surface of the façade of the high‐rise building 'KINEUM' determined from the wind tunnel measurements.
    Praha: Fenestra Wieden, 2019. 92 s.
    Institutional support: RVO:68378297
    Keywords : external pressure coefficient * wind load * high-rise building
    OECD category: Construction engineering, Municipal and structural engineering

    The report describes the procedure and results of the measurements of aerodynamic model of the planned high-rise building in Gothenburg in Sweden. The determined wind pressure distribution on individual surfaces of the building for several wind directions are presented in the form of external pressure coefficients. The obtained pressure coefficients are subsequently used by the client for the design of façade elements loaded by the wind.
    Permanent Link: http://hdl.handle.net/11104/0303894

     
     
Number of the records: 1  