Number of the records: 1  

Laboratorní separace methanolu z azeotropické směsi (25 wt% methanol a 75 wt% trimethylborát).

  1. 1.
    SYSNO ASEP0496721
    Document TypeV - Research Report
    R&D Document TypeO - Ostatní
    TitleLaboratorní separace methanolu z azeotropické směsi (25 wt% methanol a 75 wt% trimethylborát).
    TitleLaboratory Separation of Methanol from the Azeotropic Mixture (25 wt% Methanol and 75 wt% trimethylborate.
    Author(s) Gaálová, Jana (UCHP-M) RID, SAI, ORCID
    Vojtek, Lukáš (UCHP-M)
    Izák, Pavel (UCHP-M) RID, ORCID, SAI
    Issue dataPraha: Ústav chemických procesů AV ČR, v. v. i., 2018
    Series number4
    Number of pages8 s.
    Publication formPrint - P
    Languagecze - Czech
    CountryCZ - Czech Republic
    Keywordsmethanol ; separation ; membranes
    Subject RIVCI - Industrial Chemistry, Chemical Engineering
    OECD categoryChemical process engineering
    Institutional supportUCHP-M - RVO:67985858
    AnnotationPráce se zabývá laboratorní separací methanolu z azeotropické směsi (25 wt% methanol a 75 wt% trimethylborát). Byly testovány 4 různé průmyslově vyráběné membrány. U všech kromě jedné separace probíhala více méně úspěšně. U PVA 4155-80/2871 separace probíhala s dobrými výsledky, ale velice pomalu, podmínkou, která by mohla zvýšit rychlost reakce by mohlo být zvýšení teploty. Nejlépe z membrán od společnosti Sulzer dělila PDMS 4155 -30/305 R, která separovala MeOH s vysokou účinností a také dostatečně rychle. Naprosto opačný efekt pak měla membrána PDMS 4060, která místo MeOH separovala Trimethylborát.
    Description in EnglishThe work deals with laboratory separation of methanol from the azeotropic mixture (25 wt% methanol and 75 wt% trimethylborate). Four different manufactured membranes were tested. For all except one separation, separation was more or less successful. With PVA 4155-80 / 2871 the separation proceeded with good results, but very slowly, a condition that could increase the reaction rate could be an increase of temperature. Most selective membrane from Sulzer was PDMS 4155 -30/305 R, which separated MeOH with high efficiency and fast enough. The completely opposite effect than pervious membranes had the membrane PDMS 4060, which instead of MeOH separated Trimethylborate.
    WorkplaceInstitute of Chemical Process Fundamentals
    ContactEva Jirsová, jirsova@icpf.cas.cz, Tel.: 220 390 227
    Year of Publishing2019