Number of the records: 1  

Ion Source with Laser Triangulation for Ambient Mass Spectrometry of Nonplanar Samples

  1. 1.
    SYSNO ASEP0482600
    Document TypeJ - Journal Article
    R&D Document TypeJournal Article
    Subsidiary JČlánek ve WOS
    TitleIon Source with Laser Triangulation for Ambient Mass Spectrometry of Nonplanar Samples
    Author(s) Rejšek, Jan (UOCHB-X)
    Vrkoslav, Vladimír (UOCHB-X) RID, ORCID
    Pokorný, Vít (UOCHB-X)
    Přibyl, Vladimír (UOCHB-X)
    Cvačka, Josef (UOCHB-X) RID, ORCID
    Source TitleAnalytical Chemistry. - : American Chemical Society - ISSN 0003-2700
    Roč. 89, č. 21 (2017), s. 11452-11459
    Number of pages8 s.
    Languageeng - English
    CountryUS - United States
    Keywordsdesorption electrospray ionization ; atmospheric pressure photoionization ; metabolites
    Subject RIVCB - Analytical Chemistry, Separation
    OECD categoryAnalytical chemistry
    Institutional supportUOCHB-X - RVO:61388963
    UT WOS000414887000043
    DOI10.1021/acs.analchem.7b02568
    AnnotationThe analysis of nonplanar samples in ambient mass spectrometry poses a formidable challenge. Here, an ion source equipped with laser triangulation for analyzing nonplanar surfaces was constructed. It was designed as a two-position device, where the sample height was measured using laser triangulation and the target compounds were then analyzed. Thanks to a stage movable in xyz, the ion source maintained an optimal vertical distance between the sample and the sampling capillary for each measured spot during the surface analysis. The xyz-coordinates for the movement of the sample stage were computed using the laser sensor data in such a way as to avoid direct contact of the sampling capillary and the measured surface. The ion source performance and its ability to analyze various morphologies were tested using desorption electrospray ionization with plastic objects coated by 2,5-dimethoxybenzoic acid. The experiments showed excellent performance for nonplanar samples but also revealed some limitations especially on object edges and steep slopes. The applicability of the ion source operated in desorption electrospray ionization and desorption atmospheric pressure photoionization was examined for food and pharmaceutical samples. Chemicals on the surface of nonplanar samples were probed along a line extending across the surface of the measured objects. The device provided high-quality spectra, regardless of the sample height at the measured spot. The automatic adjustments of the sample stage in xyz proved to be beneficial for analyzing nonplanar samples and for simultaneous measurement of samples with various dimensions and shapes.
    WorkplaceInstitute of Organic Chemistry and Biochemistry
    Contactasep@uochb.cas.cz ; Kateřina Šperková, Tel.: 232 002 584 ; Jana Procházková, Tel.: 220 183 418
    Year of Publishing2018
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.