Number of the records: 1  

The Application of Miniaturized Three-Point-Bend Specimens for Determination of the Reference Temperature of A533 Cl.1 Steel

  1. 1.
    SYSNO ASEP0481466
    Document TypeJ - Journal Article
    R&D Document TypeJournal Article
    Subsidiary JČlánek ve WOS
    TitleThe Application of Miniaturized Three-Point-Bend Specimens for Determination of the Reference Temperature of A533 Cl.1 Steel
    Author(s) Stratil, Luděk (UFM-A) ORCID
    Šiška, Filip (UFM-A) RID, ORCID
    Dlouhý, Ivo (UFM-A) RID, ORCID
    Serrano, M. (ES)
    Number of authors4
    Article number041410
    Source TitleJournal of Pressure Vessel Technology-Transactions of the Asme - ISSN 0094-9930
    Roč. 139, č. 4 (2017)
    Number of pages6 s.
    Languageeng - English
    CountryUS - United States
    Keywordsfracture toughness ; Master Curve ; the reference temperature ; JRQ steel ; miniaturized specimens
    Subject RIVJL - Materials Fatigue, Friction Mechanics
    OECD categoryAudio engineering, reliability analysis
    R&D ProjectsGJ15-21292Y GA ČR - Czech Science Foundation (CSF)
    ED1.1.00/02.0068 GA MŠMT - Ministry of Education, Youth and Sports (MEYS)
    Institutional supportUFM-A - RVO:68081723
    UT WOS000403902100022
    EID SCOPUS85019699188
    DOI10.1115/1.4036532
    AnnotationThis contribution deals with the determination of the reference temperature of JRQ steel using miniaturized
    specimens. The dimensions of the miniaturized specimens used were 3 × 4 × 27 mm (thickness × width ×
    length). This specimen type allows utilizing a limited amount of test material or the broken halves of pre-cracked
    Charpy or larger specimens. The test material comes from the broken halves of 0.5T SE(B) specimens
    previously tested for the determination of the reference temperature at Ciemat, Madrid. The fracture toughness
    tests were performed in the transition region of the steel according to the recommendations of the standard
    ASTM E1921 and according to Wallin’s recommended temperature range of miniaturized specimens. The
    reference temperature of the Master Curve was very similar to the ones obtained from three-point-bend
    specimens of sizes 0.2T, 0.4T and 0.5T. The results obtained confirm a necessity to conduct tests at low
    temperatures and to test a sufficient number of specimens in order to generate enough valid data for the
    determination of the reference temperature.
    WorkplaceInstitute of Physics of Materials
    ContactYvonna Šrámková, sramkova@ipm.cz, Tel.: 532 290 485