Number of the records: 1  

Effect of a static magnetic field on Escherichia coli adhesion and orientation

  1. 1.
    0469631 - ÚFE 2017 RIV CA eng J - Journal Article
    Mhamdi, L. - Mhamdi, N. - Mhamdi, Nc. - Lejeune, M. - Jaffrezic, N. - Burais, N. - Scorretti, R. - Pokorný, Jiří - Ponsonnet, L.
    Effect of a static magnetic field on Escherichia coli adhesion and orientation.
    Canadian Journal of Microbiology. Roč. 62, č. 11 (2016), s. 944-952. ISSN 0008-4166. E-ISSN 1480-3275
    Institutional support: RVO:67985882
    Keywords : Fluorescence microscopy * Static magnetic field * Escherichia coli
    Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering
    Impact factor: 1.462, year: 2016

    This preliminary study focused on the effect of exposure to 0.5 T static magnetic fields on Escherichia coli adhesion and orientation. We investigated the difference in bacterial adhesion on the surface of glass and indium tin oxide-coated glass when exposed to a magnetic field either perpendicular or parallel to the adhesion surface (vectors of magnetic induction are perpendicular or parallel to the adhesion surface, respectively). Control cultures were simultaneously grown under identical conditions but without exposure to the magnetic field. We observed a decrease in cell adhesion after exposure to the magnetic field. Orientation of bacteria cells was affected after exposure to a parallel magnetic field. On the other hand, no effect on the orientation of bacteria cells was observed after exposure to a perpendicular magnetic field
    Permanent Link: http://hdl.handle.net/11104/0267455

     
     
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.