Number of the records: 1  

Non-linear ultrasonic time-reversal mirrors in NDT

  1. 1.
    0388400 - ÚT 2013 IT eng A - Abstract
    Převorovský, Zdeněk
    Non-linear ultrasonic time-reversal mirrors in NDT.
    Lectio Materia. -, č. 4 (2012), s. 4-4
    [World Conference on Nondestructive Testing /18./. 16.4.2012-20.4.2012, Durban]
    R&D Projects: GA MPO(CZ) FR-TI1/274; GA MPO(CZ) FR-T1/198; GA ČR(CZ) GAP104/10/1430
    Institutional research plan: CEZ:AV0Z2076919
    Keywords : non-linear ime reversal mirror * ultrasonic techniques * ESAM
    Subject RIV: BI - Acoustics
    http://www.academia-ndt.org/Downloads/AcademiaNews4.pdf

    Various NDT techniques based on non-linear time-reversal mirrors (NL TRM) were developed during the last few years and have already been utilised in practice. Different modifications involve, for example, pulse inversion, frequency intermodulation, harmonic filtration, time shifting, decomposition of time reversal (TR) operator (DORT), excitation with symmetry analysis (ESAM) or chirp coding. Piezoelectric transducers are mostly used as both wave transmitters and receivers, and multiplexers switch between modes. Also, the non-contact receiving is realised using laser interferometers or air-coupled transducers. In that case, the reciprocity principle is applied – an array of transmitters is used as a source of both forward and TR waves. Ultrasonic NL TRM techniques are today under intensive development and are becoming very promising in the NDT and structural health monitoring fields.
    Permanent Link: http://hdl.handle.net/11104/0217439

     
     