Number of the records: 1
Significance of independent radon entry rate and air exchange rate assessment for the purpose of radon mitigation effectiveness proper evaluation: case studies
- 1.0360283 - ÚI 2012 RIV GB eng J - Journal Article
Froňka, A. - Jílek, K. - Moučka, L. - Brabec, Marek
Significance of independent radon entry rate and air exchange rate assessment for the purpose of radon mitigation effectiveness proper evaluation: case studies.
Radiation Protection Dosimetry. Roč. 145, 2-3 (2011), s. 133-137. ISSN 0144-8420. E-ISSN 1742-3406
Institutional research plan: CEZ:AV0Z10300504
Keywords : indoor radon * kalman filter * state-space modeling
Subject RIV: BB - Applied Statistics, Operational Research
Impact factor: 0.822, year: 2011
Two new single-family houses identified as insufficient with regard to existing radon barrier efficiency, have been selected for further examination. A complex set of radon diagnosis procedures has been applied in order to localise and quantify radon entry pathways into the indoor environment. Independent assessment of radon entry rate and air exchange rate has been carried out using the continuous indoor radon measurement and a specific tracer gas application. Simultaneous assessment of these key determining factors has turned out to be absolutely crucial in the context of major cause identification of elevated indoor radon concentration.
Permanent Link: http://hdl.handle.net/11104/0197871