Number of the records: 1  

Measurement of small-signal gain on COIL with chemically generated molecular iodine

  1. 1.
    SYSNO ASEP0353726
    Document TypeJ - Journal Article
    R&D Document TypeJournal Article
    Subsidiary JČlánek ve WOS
    TitleMeasurement of small-signal gain on COIL with chemically generated molecular iodine
    Author(s) Jirásek, Vít (FZU-D) RID
    Špalek, Otomar (FZU-D)
    Čenský, Miroslav (FZU-D) RID
    Kodymová, Jarmila (FZU-D) RID
    Source TitleIEEE Journal of Quantum Electronics - ISSN 0018-9197
    Roč. 46, č. 9 (2010), s. 1350-1353
    Number of pages4 s.
    Languageeng - English
    CountryUS - United States
    Keywordschemical lasers ; iodine ; gain measurement
    Subject RIVBH - Optics, Masers, Lasers
    CEZAV0Z10100523 - FZU-D (2005-2011)
    UT WOS000282564000003
    DOI10.1109/JQE.2010.2048555
    AnnotationA chemical gas-phase reaction between Cl2 and HI was used in the generation of molecular iodine for the chemical oxygen-iodine laser (COIL) operation. A yield of I2 in the generation reaction up to 85% was achieved in a reasonable volume of the reactor. A small-signal gain up to 0.75 %/cm at a temperature of 150 K in the center of supersonic cavity was measured. A comparison with the established evaporation way of I2 delivery confirmed that the chemical method has little or no impact on the COIL pumping kinetics. This chemical method is easily scalable and can simplify the COIL operation by providing better control of I2 flow rate.