Nonlinear FE modelling of deformation behaviour of trabecular bone microstructure compared to time-lapse micro-CT measurements.
Proceedings of 9th International Symposium on Computer methods in Biomechanics and Biomedical Engineering. Cardiff: ARUP, 2010 - (Middleton, J.), s. 184-189. ISBN 978-0-9562121-3-9.
[International symposium on Computer methods in biomechanics and biomedial engineering /9./. Valencia (ES), 24.02.2010-27.02.2010]
R&D Projects: GA ČR(CZ) GAP105/10/2305
Institutional research plan: CEZ:AV0Z20710524
Keywords : micro-CT * microstructural FE model * trabecular bone
Subject RIV: JJ - Other Materials
Deformation behaviour of a cylindrical sample of trabecular bone was computed using high-resolution microstructural FE model and compared to experimental data captured using a custom micro-CT device. The strain in the sample during the whole experiment was assessed using a digital volume correlation method. The stress-strain curve of the experiment was assessed from the reactions calculated in the FE simulation and compared to the measured response of the sample.