Number of the records: 1  

EFFECT OF VORTEX GENERATORS ON FLOW CONDITIONS OF AIRFOIL WITH DEFLECTED FLAP

  1. 1.
    SYSNO ASEP0351475
    Document TypeC - Proceedings Paper (int. conf.)
    R&D Document TypeConference Paper
    TitleEFFECT OF VORTEX GENERATORS ON FLOW CONDITIONS OF AIRFOIL WITH DEFLECTED FLAP
    Author(s) Součková, Natálie (UT-L)
    Popelka, Lukáš (UT-L)
    Matějka, M. (CZ)
    Šimurda, David (UT-L) RID, ORCID
    Number of authors4
    Source Title21st International Symposium on Transport Phenomena. - Kaohsiung City : National Kaohsiung University of Applied Sciences, 2010 - ISBN 978-986-6184-25-3
    Pagess. 16-24
    Number of pages8 s.
    ActionInternational Symposium on Transport Phenomena /21./
    Event date02.11.2010-05.11.2010
    VEvent locationKaohsiung City
    CountryTW - Taiwan, Province of China
    Event typeWRD
    Languageeng - English
    CountryTW - Taiwan, Province of China
    Keywordsvortex generators ; airfoil ; flap
    Subject RIVJU - Aeronautics, Aerodynamics, Aircrafts
    R&D Projects1M06031 GA MŠMT - Ministry of Education, Youth and Sports (MEYS)
    GA101/08/1112 GA ČR - Czech Science Foundation (CSF)
    GAP101/10/1230 GA ČR - Czech Science Foundation (CSF)
    CEZAV0Z20760514 - UT-L (2005-2011)
    AnnotationThis paper focuses on a suppression of the flow separation, which occurs on a deflected flap, by means of vortex generators (VGs). An airfoil NACA 63A421 with a simple flap and vane-type vortex generators were used. The investigation was carried out by using experimental and numerical methods. The data from the numerical simulation of the flapped airfoil without VGs control were used for the vortex generator design. Two sizes, two different shapes and various spacing of the vortex generators were tested. The flow past the airfoil was visualized through two methods, namely tuft filaments technique and oil visualization. The experiments were performed in closed circuit wind tunnels with closed and open test sections. The lift curves for both cases with and without vortex generators were acquired for the determination of the lift coefficient improvement. The improvement was achieved for several cases by means all of the applied methods.
    WorkplaceInstitute of Thermomechanics
    ContactMarie Kajprová, kajprova@it.cas.cz, Tel.: 266 053 154 ; Jana Lahovská, jaja@it.cas.cz, Tel.: 266 053 823
    Year of Publishing2011
Number of the records: 1  