Number of the records: 1  

Comparison of ground sections, paraffin sections and micro-CT imaging of bone from the epiphysis of the porcine femur for morphometric evaluation

  1. 1.
    0503179 - ÚŽFG 2019 RIV DE eng J - Journal Article
    Kubíková, T. - Bartoš, M. - Juhás, Štefan - Suchý, Tomáš - Sauerová, P. - Hubálek Kubačová, M. - Tonar, Z.
    Comparison of ground sections, paraffin sections and micro-CT imaging of bone from the epiphysis of the porcine femur for morphometric evaluation.
    Annals of Anatomy-Anatomischer Anzeiger. Roč. 220, č. 1 (2018), s. 85-96. ISSN 0940-9602. E-ISSN 1618-0402
    R&D Projects: GA MZd(CZ) NV15-25813A; GA MŠMT(CZ) LO1609
    Institutional support: RVO:67985904 ; RVO:67985891
    Keywords : stereology * cortical compact bone * trabecular bone * histomorphometry * bone volume * pig
    OECD category: Anatomy and morphology (plant science to be 1.6); Anatomy and morphology (plant science to be 1.6) (USMH-B)
    Impact factor: 2.241, year: 2018
    https://doi.org/10.1016/j.aanat.2018.07.004

    The aim of this study was to compare data on the volume fraction of bone and the thickness of the cortical compact bone acquired during microcomputed tomography (micro-CT) analysis with data acquired from identical samples using stereological analysis of either decalcified paraffin sections or ground sections. Additionally, we aimed to compare adjacent tissue samples taken from the major trochanter of the porcine femur to map the basic biological variability of trabecular bone.
    Permanent Link: http://hdl.handle.net/11104/0294995

     
     
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.