Number of the records: 1  

Polymer brush-functionalized chitosan hydrogels as antifouling implant coatings

  1. 1.
    0475191 - ÚMCH 2018 RIV US eng J - Journal Article
    Buzzacchera, I. - Vorobii, M. - Kostina, N. Yu. - de los Santos Pereira, Andres - Riedel, Tomáš - Bruns, M. - Ogieglo, W. - Möller, M. - Wilson, C. J. - Rodriguez-Emmenegger, C.
    Polymer brush-functionalized chitosan hydrogels as antifouling implant coatings.
    Biomacromolecules. Roč. 18, č. 6 (2017), s. 1983-1992. ISSN 1525-7797. E-ISSN 1526-4602
    R&D Projects: GA ČR(CZ) GBP205/12/G118
    Institutional support: RVO:61389013
    Keywords : chitosan * hemocompatible * polymer brushes
    OECD category: Biochemistry and molecular biology
    Impact factor: 5.738, year: 2017

    Implantable sensor devices require coatings that efficiently interface with the tissue environment to mediate biochemical analysis. In this regard, bioinspired polymer hydrogels offer an attractive and abundant source of coating materials. However, upon implantation these materials generally elicit inflammation and the foreign body reaction as a consequence of protein fouling on their surface and concomitant poor hemocompatibility. In this report we investigate a strategy to endow chitosan hydrogel coatings with antifouling properties by the grafting of polymer brushes in a “grafting-from” approach. Chitosan coatings were functionalized with polymer brushes of oligo(ethylene glycol) methyl ether methacrylate and 2-hydroxyethyl methacrylate using photoinduced single electron transfer living radical polymerization and the surfaces were thoroughly characterized by XPS, AFM, water contact angle goniometry, and in situ ellipsometry. The antifouling properties of these new bioinspired hydrogel-brush coatings were investigated by surface plasmon resonance. The influence of the modifications to the chitosan on hemocompatibility was assessed by contacting the surfaces with platelets and leukocytes. The coatings were hydrophilic and reached a thickness of up to 180 nm within 30 min of polymerization. The functionalization of the surface with polymer brushes significantly reduced the protein fouling and eliminated platelet activation and leukocyte adhesion. This methodology offers a facile route to functionalizing implantable sensor systems with antifouling coatings that improve hemocompatibility and pave the way for enhanced device integration in tissue.
    Permanent Link: http://hdl.handle.net/11104/0272504

     
     