Number of the records: 1  

Innovations at the MT 25 microtron aimed at applications in photon activation analysis

  1. 1.
    0443437 - ÚJF 2016 RIV NL eng J - Journal Article
    Krist, Pavel - Horák, Zbyněk - Mizera, Jiří - Chvátil, David - Vognar, Miroslav - Řanda, Zdeněk
    Innovations at the MT 25 microtron aimed at applications in photon activation analysis.
    Journal of Radioanalytical and Nuclear Chemistry. Roč. 304, č. 1 (2015), s. 183-188. ISSN 0236-5731. E-ISSN 1588-2780
    R&D Projects: GA ČR GA13-27885S; GA ČR(CZ) GBP108/12/G108
    Institutional support: RVO:61389005
    Keywords : microtron * electron accelerator * photon activation analysis * IPAA * short-lived radionuclides * pneumatic tube delivery system
    Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders
    Impact factor: 0.983, year: 2015

    Microtron MT 25 is an effective source of high energy photon radiation in photon activation analysis (PAA). Recent modernization of MT 25 was aimed at upgrading its parameters such as the mean accelerated electron current, quality of the beam and irradiation fields, and long-run operation stability and reliability. A fuzzy system for automated control of the current and energy of the accelerated electrons has been designed. Installation of an automated pneumatic tube delivery system for rapid sample transport between the beam position and detector will provide extension of the analytical range of PAA in the short time irradiation mode.