Number of the records: 1  

Pump for extremely dangerous liquids

  1. 1.
    0360098 - ÚT 2012 RIV GB eng J - Journal Article
    Tesař, Václav
    Pump for extremely dangerous liquids.
    Chemical Engineering Research and Design. Roč. 89, č. 7A (2011), s. 940-956. ISSN 0263-8762. E-ISSN 1744-3563
    R&D Projects: GA ČR GA101/07/1499; GA AV ČR IAA200760705
    Institutional research plan: CEZ:AV0Z20760514
    Keywords : pump * jet pump * coanda effect
    Subject RIV: BK - Fluid Dynamics
    Impact factor: 1.968, year: 2011
    http://www.sciencedirect.com/science/article/pii/S0263876210003631

    The described pump is robust and may be made of materials withstanding high temperature, chemical aggressiveness of the liquid, or special conditions like exposure to radioactivity. It is driven by a two-phase alternating air flow acting in vertical displacement tubes. In parts coming into contact with the liquid the pump has no moving or deformed components. It is thus leak-proof, extremely reliable, and needs no maintenance. The rectifier is a series-connected array of jet-pumps, each odd one connected to one phase of the driving air flow – and each even one the other phase.
    Permanent Link: http://hdl.handle.net/11104/0197732

     
     
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.