Number of the records: 1  

Evaluation of strain field in microstructures using micro-CT and digital volume correlation

  1. 1.
    0354592 - ÚTAM 2011 RIV GB eng J - Journal Article
    Jiroušek, Ondřej - Jandejsek, Ivan - Vavřík, Daniel
    Evaluation of strain field in microstructures using micro-CT and digital volume correlation.
    Journal of Instrumentation. Roč. 6, January (2011), s. 1-5. ISSN 1748-0221. E-ISSN 1748-0221.
    [International workshop on radiation imaging detectors /12./. Cambridge, 12.07.2010-15.07.2010]
    R&D Projects: GA ČR(CZ) GAP105/10/2305
    Institutional research plan: CEZ:AV0Z20710524
    Keywords : inspection with x-rays * overall mechanics design * pixelated detectors and associated VLSI electronics
    Subject RIV: JJ - Other Materials
    Impact factor: 1.869, year: 2011
    http://iopscience.iop.org/1748-0221/6/01/C01039

    X-ray digital micro-tomography was employed for precise strain measurement which is essential for evaluation of the experiments with small samples of trabecular bone. X-ray Digital Volumetric Correlation (DVC) method was used to identify the three-dimensional strain field in loaded complex microstructure. DVC relies on tracking selected sample points within the threedimensional image data throughout the sequence of captured projections. In this study an improved DVC method is applied for evaluation of the strain field in trabecular bone sample subjected to compressive loading. The deformed sample was tomographically scanned using micro-focus X-ray tube and the single-photon counting silicon pixel detector Medipix2.
    Permanent Link: http://hdl.handle.net/11104/0193562

     
     
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.