X-ray dynamic defectoscopy utilizing digital image correlation

  1. 1.
    0350922 - ÚTAM 2012 RIV NL eng J - Journal Article
    Jandejsek, Ivan - Nachtrab, F. - Uhlmann, N. - Vavřík, Daniel
    X-ray dynamic defectoscopy utilizing digital image correlation.
    Nuclear Instruments & Methods in Physics Research Section A. Roč. 6, č. 5 (2011), s. 185-186. ISSN 0168-9002. E-ISSN 1872-9576.
    [International workshop on Radiation imaging detectors /11./. Praha, 28.06.2009-02.07.2009]
    R&D Projects: GA ČR(CZ) GA103/09/2101
    Institutional research plan: CEZ:AV0Z20710524
    Keywords : Computed tomography * X-ray Defectoscopy * non-contact technique
    Subject RIV: JL - Materials Fatigue, Friction Mechanics
    Impact factor: 1.207, year: 2011

    This paper presents the utilization of the image processing technique known as digital image correlation for X-ray dynamic defectoscopy purpose. Digital image correlation is a non-contact technique that provides measurement of deformation fields within an object subjected to loading. In this case it was used for crack detection in a bar specimen subjected to tension loading.