    Strain analysis of trabecular bone using time-resolved X-ray microtomography.
    Nuclear Instruments & Methods in Physics Research Section A. Roč. 633, Suppl. 1 (2011), s. 148-151. ISSN 0168-9002. E-ISSN 1872-9576.
    [International Workshop on Radiation Imaging Detectors /11./. Praha, 28.06.2009-02.07.2009]
    R&D Projects: GA ČR(CZ) GP103/07/P483
    Institutional research plan: CEZ:AV0Z20710524
    Keywords : trabecular bone * X-ray microtomography * strain analysis * intrinsic material properties
    Subject RIV: JB - Sensors, Measurment, Regulation
    Impact factor: 1.207, year: 2011

    A micro-radiographic system composed of microfocus X-ray tube and a large flat panel detector has been adapted for imaging complicated internal microstructure of trabecular bone under applied deformation. From the reconstructed cross-sections a finite element model of the microstructure was developed and loaded according to the experiment. Deformation behavior of the FE model was compared to the experimentally determined response of the sample.