Number of the records: 1  

Experimental Determination of Human Arm Force/Elbow Joint Angle Relation

  1. 1.
    0343566 - ÚT 2011 RIV CZ eng C - Conference Paper (international conference)
    Krejsa, Jiří - Zezula, M. - Věchet, Stanislav
    Experimental Determination of Human Arm Force/Elbow Joint Angle Relation.
    Engineering Mechanics 2010. Prague: Institute of Thermomechanics AS CR, v. v. i., 2010 - (Zolotarev, I.), s. 79-80. ISBN 978-80-87012-26-0.
    [Engineering Mechanics 2010. Svratka (CZ), 10.05.2010-13.05.2010]
    Institutional research plan: CEZ:AV0Z20760514
    Keywords : intelligent orthosis * human arm force measurement
    Subject RIV: JB - Sensors, Measurment, Regulation
    http://www.engmech.cz/

    The achievable force at the end of human forearm depends on the forearm position. The actual value of this force is one of the most important variables affecting the design of the motorized splint, but reliable data are hard to find. Sophisticated measuring device was constructed to determine this force. The force is measured during the movement of the forearm, as such method yields better results than static measurement. The trajectory of movement is enforced by the measuring device, so the influence of the subject on the trajectory is eliminated.
    Permanent Link: http://hdl.handle.net/11104/0186016

     
     
Number of the records: 1  