Time-resolved tomographic measurements of temperatures in a thermal plasma jet

  1. 1.
    0337730 - ÚT 2010 RIV GB eng J - Journal Article
    Hlína, Jan - Šonský, Jiří
    Time-resolved tomographic measurements of temperatures in a thermal plasma jet.
    Journal of Physics D-Applied Physics. Roč. 43, č. 5 (2010), s. 1-9. ISSN 0022-3727. E-ISSN 1361-6463
    Institutional research plan: CEZ:AV0Z20570509
    Keywords : thermal plasma jet * optical diagnostics * temperature distribution
    Subject RIV: BL - Plasma and Gas Discharge Physics
    Impact factor: 2.105, year: 2010

    Temperatures in a thermal plasma jet were measured using an experimental set-up providing time-resolved scans of plasma optical radiation near 650 nm from 4 directions. The acquired data were used for reconstructions of time-resolved temperature distributions in measurement planes perpendicular to the plasma jet axis. The plasma torch was fed by the d.c. power source with a substantial ripple voltage modulation which leads to significant differences between the temperature distributions according to the actual phase of the arc current.
    Permanent Link: http://hdl.handle.net/11104/0181659

     
     