Analysis of microcracks caused by drop shatter testing of porcine kidneys
- 1.0327877 - FGÚ 2010 RIV DE eng J - Journal Article
Tonar, Z. - Janáček, Jiří - Nedorost, L. - Grill, R. - Báča, V. - Záťura, F.
Analysis of microcracks caused by drop shatter testing of porcine kidneys.
[Analýza mikrotrhlin způsobených pádovým testem v ledvině vepře.]
Annals of Anatomy-Anatomischer Anzeiger. Roč. 191, č. 3 (2009), s. 294-308. ISSN 0940-9602. E-ISSN 1618-0402
R&D Projects: GA AV ČR(CZ) IAA100110502
Institutional research plan: CEZ:AV0Z50110509
Keywords : kidney * rupture * stereology
Subject RIV: FP - Other Medical Disciplines
Impact factor: 0.877, year: 2009
Cortex and medula were both damaged after drop shatter test, even in those areas of kidneys, that were free of macroscopic cracks on the surface. The ruptures propagated preferentially through the interstitial connective tissue. The most affected vessels were the arcuate veins followed by the arcuate arteries
Nejvýraznější změny kůry a dřeně ledvin po simulovaném traumatu jsou ruptury vedoucí přednostně řídkým kolagenním vazivem. Z cév byly nejvíce poškozené vv. arcutae, poškozené byly i aa. arcutae