Number of the records: 1  

Calibration of Constitutive Model for Trabecular Bone Based on Nanoindentation

  1. 1.
    0324700 - ÚTAM 2009 RIV CZ eng C - Conference Paper (international conference)
    Zlámal, Petr - Jiroušek, Ondřej - Němeček, J.
    Calibration of Constitutive Model for Trabecular Bone Based on Nanoindentation.
    [Kalibrace konstitutivního modelu trabekulární kosti na základě nanoindentace.]
    Engineering Mechanics 2009. Praha: ÚTAM, 2009 - (Náprstek,, J.; Fischer, C.), s. 314-315. ISBN 978-80-86246-35-2.
    [Engineering mechanics 2009. Svratka (CZ), 11.05.2009-14.05.2009]
    R&D Projects: GA ČR(CZ) GP103/07/P483
    Institutional research plan: CEZ:AV0Z20710524
    Keywords : trabecular bone * nanoindentation * FEA
    Subject RIV: FI - Traumatology, Orthopedics

    The paper deals with investigation of a trabecular bone behaviour during nanoindentation test. Behavior of trabecular bone is investigated using real nanoindentation and finite element simulation. Two different plasticity criteria for material model of trabeculae are tested, namely von Mises and Drucker-Prager. Von Mises criterium is extended bilinear isotropic hardening. Constants needed for numerical material model are obtained from fitting procedure of a experimetal load-displacement curve.

    Práce zkoumá chování trabekulární kosti v průběhu nanoindentačního experimentu. Deformační chování je jednak zkoumáno za pomocí reálného nanoindentačního experimentu, tak i za pomocí numerické simulace testu. Jako podmínky plasticity pro MKP analýzu jsou použity kritéria dle von Misese s izotropním zpevněním a Drucker-Pragerova podmínka plasticity. Materiálové konstaty potřebné pro numerický model jsou obdrženy z porovnání experimentální křivky s křivkami z numerických simulací.
    Permanent Link: http://hdl.handle.net/11104/0172327

     
     