Number of the records: 1
Influence of rate of change of magnetization processes on sensitivity of magnetic adaptive testing
- 1.0324686 - FZÚ 2009 RIV NL eng J - Journal Article
Tomáš, Ivan - Vértesy, G. - Kadlecová, Jana
Influence of rate of change of magnetization processes on sensitivity of magnetic adaptive testing.
[Vliv rychlosti změn magnetizačních procesů na citlivost magnetického adaptivního testování.]
Journal of Magnetism and Magnetic Materials. Roč. 321, č. 8 (2009), s. 1019-1024. ISSN 0304-8853. E-ISSN 1873-4766
R&D Projects: GA AV ČR 1QS100100508
Grant - others:HSRF(HU) K-62466
Institutional research plan: CEZ:AV0Z10100520
Keywords : magnetic adaptive testing * nondestructive testing * ferromagnetic materials
Subject RIV: BM - Solid Matter Physics ; Magnetism
Impact factor: 1.204, year: 2009
Dependence of sensitivity of degradation functions in the method of Magnetic Adaptive Testing is analyzed in this paper. It is shown that whereas sensitivity of the top-responsive degradation functions from around the top permeability of the non-degraded (reference) material drops down with increasing magnetizing field-slope, sensitivity of the mild-responsive degradation functions from regions with lower permeability of the reference material is frequently magnetizing field-slope-independent.
V článku je analyzována závislost citlivosti degradačních funkcí při aplikaci metody magnetického adaptivního testování. Ukazuje se, že zatímco citlivost nejcitlivějších degradačních funkcí z oblasti maxima permeability nedegradovaného (referenčního) materiálu klesá se zvyšující se rychlostí změny magnetizačního pole, citlivost méně citlivých degradačních funkcí z oblastí s nižší permeabilitou referenčního materiálu bývá často na rychlosti změny magnetizačního pole nezávislá.
Permanent Link: http://hdl.handle.net/11104/0172317