Number of the records: 1  

Optimizing Conditions for Ultrasound Extraction of Fullerenes from Coal Matrices

  1. 1.
    0323532 - ÚFCH JH 2009 RIV US eng J - Journal Article
    Vítek, P. - Jehlička, J. - Frank, Otakar - Hamplová, Věra - Pokorná, Zdeňka - Juha, Libor - Boháček, J.
    Optimizing Conditions for Ultrasound Extraction of Fullerenes from Coal Matrices.
    [Optimalizace podmínek pro ultrazvukovou extrakci fullerenů z uhelné matrice.]
    Fullerenes, Nanotubes, and Carbon Nanostructures. Roč. 17, č. 2 (2009), s. 109-122. ISSN 1536-383X. E-ISSN 1536-4046
    R&D Projects: GA ČR GA205/07/0772; GA ČR GA205/03/1468
    Institutional research plan: CEZ:AV0Z40400503; CEZ:AV0Z10100520
    Keywords : fullerene C60 * Ultrasound-assisted extraction * Extraction yield * Fullerene decomposition
    Subject RIV: CF - Physical ; Theoretical Chemistry
    Impact factor: 0.710, year: 2009

    Conditions for ultrasound toluene extraction of synthetic C60 added to powdered bituminous coal were tested. The best conditions for C60 recovery in the investigated mixtures are 30 min of sonication at 280–285 K. The effects of sample filtration, sequential extraction, ultrasound bath power and treatments of C60 solution alone are also discussed.

    Byly testovány podmínky pro ultrazvukovou extrakci syntetického C60 přidaného do rozemletého černého uhlí. Největšího výtěžku C60 bylo dosaženo při sonikaci po dobu 30 minut a teplotě 280-285 K. Jsou diskutovány efekty filtrace, sekvenční extrakce, výkonu ultrazvukové lázně a úprav roztoku C60.
    Permanent Link: http://hdl.handle.net/11104/0171456

     
     