Number of the records: 1  

Effect of complexones and tensides on selectivity of nitrogen dioxide determination in air with a chemiluminescence aerosol detector

  1. 1.
    0162177 - UIACH-O 200020 RIV NL eng J - Journal Article
    Mikuška, Pavel - Večeřa, Zbyněk
    Effect of complexones and tensides on selectivity of nitrogen dioxide determination in air with a chemiluminescence aerosol detector.
    Analytica Chimica Acta. Roč. 410, 1-2 (2000), s. 159-165. ISSN 0003-2670. E-ISSN 1873-4324
    R&D Projects: GA ČR GA203/98/0943
    Grant - others:COPERNICUS(BE) SUB-AERO EVK2-1999-000327
    Subject RIV: CB - Analytical Chemistry, Separation
    Impact factor: 1.849, year: 2000
    Permanent Link: http://hdl.handle.net/11104/0059497
     

Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.