Number of the records: 1
Contribution of Visitors to the Indoor PM in the National Library in Prague, Czech Republic.
- 1.0463835 - ÚCHP 2017 RIV TW eng J - Článek v odborném periodiku
Mašková, Ludmila - Smolík, Jiří - Trávníčková, Tereza - Havlica, Jaromír - Ondráčková, Lucie - Ondráček, Jakub
Contribution of Visitors to the Indoor PM in the National Library in Prague, Czech Republic.
Aerosol and Air Quality Research. Roč. 16, č. 7 (2016), s. 1713-1721. ISSN 1680-8584. E-ISSN 2071-1409
Grant CEP: GA ČR(CZ) GAP105/12/0664
GRANT EU: European Commission(XE) 315760 - HEXACOMM
Institucionální podpora: RVO:67985858
Klíčová slova: indoor source * penetration * deposition
Kód oboru RIV: CF - Fyzikální chemie a teoretická chemie
Impakt faktor: 2.606, rok: 2016
Temporal and spatial variation of size resolved particulate matter (PM) was measured in the Baroque Library Hall of the National Library in Prague during four intensive campaigns by an Aerodynamic Particle Sizer and three DustTrak instruments. The analysis showed, the indoor air can be considered as well mixed and therefore the simple mass balance model was used to estimate basic parameters (ventilation rate, deposition rates and penetration factors). The results revealed that the movement of visitors during visiting hours is the main source of indoor coarse PM. Mass emission rates, estimated from the comparison of measured and modelled data indicates the visitors should contribute about 50 g of coarse particles yearly, which is about 35% of the total load of indoor PM.
Trvalý link: http://hdl.handle.net/11104/0262928
Number of the records: 1