Number of the records: 1
Varying Performance of Low-Cost Sensors During Seasonal Smog Events in Moravian-Silesian Region
- 1.0602548 - ÚFCH JH 2025 RIV CH eng J - Journal Article
Nevrlý, Václav - Dostál, Michal - Bitala, P. - Klečka, V. - Sléžka, J. - Polách, P. - Nevrlá, K. - Barabášová, M. - Langová, R. - Bernatíková, S. - Martiníková, B. - Vašinek, M. - Nevrlý, A. - Lazecký, M. - Suchánek, Jan - Chaloupecká, Hana - Kiča, D. - Wild, J.
Varying Performance of Low-Cost Sensors During Seasonal Smog Events in Moravian-Silesian Region.
Atmosphere. Roč. 15, č. 11 (2024), č. článku 1326. ISSN 2073-4433. E-ISSN 2073-4433
R&D Projects: GA ČR GA22-19812S; GA TA ČR(CZ) SS03010139
Institutional support: RVO:61388955 ; RVO:61388998
Keywords : air-quality sensors * calibration * pollution * air quality * low-cost sensors * Polish smog * Saharan dust storm * linear regression
OECD category: Physical chemistry; Meteorology and atmospheric sciences (UT-L)
Impact factor: 2.5, year: 2023 ; AIS: 0.553, rok: 2023
Method of publishing: Open access
DOI: https://doi.org/10.3390/atmos15111326
Air pollution monitoring in industrial regions like Moravia-Silesia faces challenges due to complex environmental conditions. Low-cost sensors offer a promising, cost-effective alternative for supplementing data from regulatory-grade air quality monitoring stations. This study evaluates the accuracy and reliability of a prototype node containing low-cost sensors for carbon monoxide (CO) and particulate matter (PM), specifically tailored for the local conditions of the Moravian-Silesian Region during winter and spring periods. An analysis of the reference data observed during the winter evaluation period showed a strong positive correlation between PM, CO, and NO2 concentrations, attributable to common pollution sources under low ambient temperature conditions and increased local heating activity. The Sensirion SPS30 sensor exhibited high linearity during the winter period but showed a systematic positive bias in PM10 readings during Polish smog episodes, likely due to fine particles from domestic heating. Conversely, during Saharan dust storm episodes, the sensor showed a negative bias, underestimating PM10 levels due to the prevalence of coarse particles. Calibration adjustments, based on the PM1/PM10 ratio derived from Alphasense OPC-N3 data, were initially explored to reduce these biases. For the first time, this study quantifies the influence of particle size distribution on the SPS30 sensor's response during smog episodes of varying origin, under the given local and seasonal conditions. In addition to sensor evaluation, we analyzed the potential use of data from the Copernicus Atmospheric Monitoring Service (CAMS) as an alternative to increasing sensor complexity. Our findings suggest that, with appropriate calibration, selected low-cost sensors can provide reliable data for monitoring air pollution episodes in the Moravian-Silesian Region and may also be used for future adjustments of CAMS model predictions.
Permanent Link: https://hdl.handle.net/11104/0359762File Download Size Commentary Version Access 0602548_atmosphere-15-01326-v3-1.pdf 1 6.4 MB Publisher’s postprint open-access 0602548.pdf 1 6.4 MB open access Publisher’s postprint open-access
Number of the records: 1