Number of the records: 1  

Improvements in digital meteor spectra reduction

  1. 1.
    0584797 - ASÚ 2025 RIV DE eng J - Journal Article
    Šegon, Marko - Vojáček, Vlastimil - Borovička, Jiří
    Improvements in digital meteor spectra reduction.
    Experimental Astronomy. Roč. 57, č. 2 (2024), č. článku 9. ISSN 0922-6435. E-ISSN 1572-9508
    R&D Projects: GA ČR(CZ) GX19-26232X
    Institutional support: RVO:67985815
    Keywords : data analysis * observational techniques * imaging spectroscopy
    OECD category: Astronomy (including astrophysics,space science)
    Impact factor: 3, year: 2022
    Method of publishing: Open access

    This study addresses the complexity and importance of developing a method of calibrating digital observations of meteor spectra with all-sky cameras. It aims to present novel approaches to spectral sensitivity, atmospheric extinction and flat-field corrections. Images of a known line emission spectrum were captured at various positions within the field of view using a camera with a fish-eye lens and plastic holographic grating. The flat-field correction was separated into a wavelength-independent and wavelength-dependent component, both dependent on the position of the spectral line in the field of view (FoV). Total profile intensities of spectra obtained from the images were compared throughout the spectral range at different positions in the FoV. The flat-field was constructed by fitting those dependencies with high-degree polynomial functions. Using a simplified atmospheric model, a novel approach was constructed to determine the atmospheric extinction curve throughout the spectral range, allowing it to be separately considered from the spectral sensitivity which was previously not the case. A comparison of the newly developed and previously used methodology was tested on several meteor spectra of the same meteor captured from different stations of the European Fireball Network. It revealed a significantly improved correspondence of the analysed spectra in the part of the spectral range unaffected by the limitations imposed by the newly developed methodology. Failing to follow the correct calibration methodology precisely may introduce varying degrees of uncertainty in computations of elemental abundances and other physical properties, depending on the equipment's specific effect magnitude.
    Permanent Link: https://hdl.handle.net/11104/0354153

     
    FileDownloadSizeCommentaryVersionAccess
    584797.pdf14.5 MBPublisher’s postprintopen-access
     
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.