Number of the records: 1  

The Micro-CT Analysis of the Structural Parameters of Collagen-based Porous Scaffolds: The Influence of Image Processing and Binarization

  1. 1.
    0566717 - ÚSMH 2024 RIV US eng J - Journal Article
    Bartoš, M. - Suchý, Tomáš - Luňáčková, J. - Soukup, P.
    The Micro-CT Analysis of the Structural Parameters of Collagen-based Porous Scaffolds: The Influence of Image Processing and Binarization.
    Microscopy and Microanalysis. Roč. 29, č. 1 (2023), s. 244-253. ISSN 1431-9276. E-ISSN 1435-8115
    R&D Projects: GA ČR(CZ) GA20-11186S
    Institutional support: RVO:67985891
    Keywords : binarization * image-processing * micro-CT * pore size * porosity * scaffold
    OECD category: Anatomy and morphology (plant science to be 1.6)
    Impact factor: 2.8, year: 2022
    Method of publishing: Open access
    https://doi.org/10.1093/micmic/ozac024

    The micro-CT evaluation of structural parameter values is dependent on the processing of the image prior to its analysis. However, the degree of bias introduced by the image-processing process is generally unknown. The micro-CT analysis of three basic parameters (volume, surface, and pore size) was performed for 20 collagen-based porous scaffolds. The image data were processed using various approaches (noise reduction, binarization), analyzed and results were compared. A high degree of variability was observed in the values of the structural parameters. The differences between the mean values were as follows: 190% (volume), 160% (surface density), and 210% (pore size). Significant differences were observed with respect to the noise reduction in terms of the pore size values (frequently in excess of 300%). Our study proved the significant dependence of image processing on the results obtained. The data presented can be used as an estimate for the introduced bias. We suggest improvements in terms of the selection of the image-processing approach based on a combination of subjective selection (the standard method) and numerical analysis based on the consistency of the results. Although we focused on tissue engineering scaffolds, the principles are similar for all fields of the micro-CT application.
    Permanent Link: https://hdl.handle.net/11104/0342613

     
    FileDownloadSizeCommentaryVersionAccess
    Bartoš-Suchý-The Micro-CT.pdf23.5 MBPublisher’s postprintopen-access
     
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.